R.J.,I would run the calibration "By The Book". There is no real magic about the 100 m distance specified except that the sight picture for both you...
Brad,The Check and Adjust procedure should only be done with a full sized circluar prism. It does not have to be a Leica prism. The reason is that t...
Donald,It sounds like the EDM board may be on the verge of failing. On the TPS1100 there should have been one EDM board for the infrared and one boar...
R.J.,The CF card is only needed while performing the check and adjust routine to write some temporary files during the tests. Once you are out of the...
Good Enough,I think this is what you are talking about.... how to put the instrument into manual mode just to measure angles and distance.On the TPS1...
DCPO,First, if the TS06 is getting moisture in that easily you need to take it back and have it inspected. No Leica Instrument should get moisture in...
Norman,I have always "battled" the point numbering method in training sessions with crews. I think it is just because in most older field software a ...
Aaron23,I may be misunderstanding what you are say about Leica makes it difficult to store points multiple times. With Leica you can store the same p...
Need Level License in LGO to processBob,There are a few ways in LGO to capture unadjusted vs. adjusted measurements but I agree that having just a pre...
Ennkis,I would not worry with the Windows CE side. Try to do everything inside SmartWorx on the RX900. The BT paring information is kept inside Sma...
Cheyenne10,When you bring in the level data into LGO you will be using the old standard GSI format or there should be a format file loaded on you DNA ...
If the NVRAM clearing does not work you have issues with the instrument and it needs to go to a Leica Service Center. I did notice that you said you...
L BAR PRISM OFFSET? For MarkMan my memory must be going to hell... I did look at my hard dive because I thought I did have this info but I did not se...
Ralph,I have honestly never seen a published offset for this prism. Can you tell me where you have seen this in a Leica manual or datasheet? I have ...
John is correct about the Leica GMP104 (Art. No, 641762) in that is is meant to be used as a monitoring prism. There is no published offset for this ...
Unfortunately the rod for the Leica Sprinter only works with the Sprinter. The DNA series will not read it.
David,As far aa I have seen each vendor basically has there own rod. I have not heard of any rod except a Leica rod working with the DNA or older NA...
Eddym,This is possible with just some settings. I got your email and will find some time today to write up the details. There are just some choices...
Dan,The issues with the CS15 are load and clear. Theses have been voiced very distinclty and Leica will listen. Leica makes the best GNSS and the be...
Dan,This is my description of the GS08 Plus system.... we having several users who purchased one of these and are happy but the system matched what th...