Reply
RE: Leica GRZ4 360° prism

R.J.,I would run the calibration "By The Book". There is no real magic about the 100 m distance specified except that the sight picture for both you...

10 years ago
Reply
RE: Leica GRZ4 360° prism

Brad,The Check and Adjust procedure should only be done with a full sized circluar prism. It does not have to be a Leica prism. The reason is that t...

10 years ago
Reply
RE: Leica tcr1105 not shooting?

Donald,It sounds like the EDM board may be on the verge of failing. On the TPS1100 there should have been one EDM board for the infrared and one boar...

10 years ago
Reply
RE: Leica TS12 - does a quick measure screen?

R.J.,The CF card is only needed while performing the check and adjust routine to write some temporary files during the tests. Once you are out of the...

10 years ago
Reply
RE: Leica TS12 - does a quick measure screen?

Good Enough,I think this is what you are talking about.... how to put the instrument into manual mode just to measure angles and distance.On the TPS1...

10 years ago
Reply
RE: trouble using a leica tribrach prism

DCPO,First, if the TS06 is getting moisture in that easily you need to take it back and have it inspected. No Leica Instrument should get moisture in...

10 years ago
Reply
RE: Best Method for Leica Viva least Squares

Norman,I have always "battled" the point numbering method in training sessions with crews. I think it is just because in most older field software a ...

10 years ago
Reply
RE: Best Method for Leica Viva least Squares

Aaron23,I may be misunderstanding what you are say about Leica makes it difficult to store points multiple times. With Leica you can store the same p...

10 years ago
Reply
RE: Leica DNA10 level raw data and reports

Need Level License in LGO to processBob,There are a few ways in LGO to capture unadjusted vs. adjusted measurements but I agree that having just a pre...

10 years ago
Reply
RE: Leica GPS900

Ennkis,I would not worry with the Windows CE side. Try to do everything inside SmartWorx on the RX900. The BT paring information is kept inside Sma...

10 years ago
Reply
RE: Leica DNA10 level raw data and reports

Cheyenne10,When you bring in the level data into LGO you will be using the old standard GSI format or there should be a format file loaded on you DNA ...

10 years ago
Reply
RE: Leica TRCP1203+ non starting

If the NVRAM clearing does not work you have issues with the instrument and it needs to go to a Leica Service Center. I did notice that you said you...

10 years ago
Reply
RE: L BAR PRISM OFFSET?

L BAR PRISM OFFSET? For MarkMan my memory must be going to hell... I did look at my hard dive because I thought I did have this info but I did not se...

10 years ago
Reply
RE: L BAR PRISM OFFSET?

Ralph,I have honestly never seen a published offset for this prism. Can you tell me where you have seen this in a Leica manual or datasheet? I have ...

10 years ago
Reply
RE: L BAR PRISM OFFSET?

John is correct about the Leica GMP104 (Art. No, 641762) in that is is meant to be used as a monitoring prism. There is no published offset for this ...

10 years ago
Reply
RE: Digital level rods?

Unfortunately the rod for the Leica Sprinter only works with the Sprinter. The DNA series will not read it.

10 years ago
Reply
RE: Digital level rods?

David,As far aa I have seen each vendor basically has there own rod. I have not heard of any rod except a Leica rod working with the DNA or older NA...

10 years ago
Reply
RE: Connect Leica GS14 to RTN through its internal modem

Eddym,This is possible with just some settings. I got your email and will find some time today to write up the details. There are just some choices...

10 years ago
Reply
RE: Robotic Total Stations

Dan,The issues with the CS15 are load and clear. Theses have been voiced very distinclty and Leica will listen. Leica makes the best GNSS and the be...

10 years ago
Reply
RE: Leica ATX1230

Dan,This is my description of the GS08 Plus system.... we having several users who purchased one of these and are happy but the system matched what th...

10 years ago