AI Assistant
Notifications
Clear all
Hoosier Surveyor
Hoosier Surveyor
@hoosier_surveyor
Free
Joined: June 23, 2015 2:48 pm
Last seen: July 9, 2026 10:20 am
Topics: 62 / Replies: 187
Topic
Reply
RE: Want to buy TSC2/Ranger Power Module

thanks - that's the way to go!

10 years ago
Forum
Reply
RE: Deed Conflict -

Yep, the (moving) creek is the boundary.But the day is starting slow, so I would like to start an argument :).1. How do we justify going back through...

10 years ago
Reply
RE: Want to buy TSC2/Ranger Power Module

Thanks for the info - do you have a guess on how much they charge?

10 years ago
Forum
Reply
RE: Civil3D Point Styles

Trundle, I don't want a block in the point style. An "X" or "+" sign is fine. I want an independent block inserted on top of (or below) the point no...

10 years ago
Reply
RE: Civil3D Point Styles

Trundle - thanks for the reply. Yes, I get it.I would rather be able use an dyanmic (and annotative) block that would allow me to grab a grip and rota...

10 years ago
Topic
Forum
Replies: 8
Views: 659
Reply
RE: Civil3D Point Styles

PA PLS,So,(1) if I would change the drawing scale to 1"=1" and make a block that is 0.1 units wide and long (think rectangular drainage grate),(2) the...

10 years ago
Topic
Replies: 12
Views: 774
Reply
RE: Civil 3D and Ground Distances

I am just looking for a standard (Template, Squirltech!) that I can employ for all surveys to account for surveying and drafting on SPC with no transf...

10 years ago
Reply
RE: Civil 3D and Ground Distances

Yes - Civil 3D has transformation settings, but it doesn't quite work for rotation. I'll try to explain to the best of my ability:1. C3D's geodetic ...

10 years ago
Reply
RE: Civil 3D and Ground Distances

Squireltech - I am kind of a freak about drafting/CADD (yes there are two D's in CADD 🙂 ) standards - therefore templates are important to me. I don...

10 years ago
Topic
Replies: 14
Views: 1522
Topic
Forum
Replies: 3
Views: 937
Topic
Reply
RE: Indiana Surveyors = Civil Engineer's?

As far as drainage goes...In Indiana, if it doesn't involve a pump or siphon, a land surveyor is allowed by state law to design it.

10 years ago
Reply
RE: Countersinking Shiners

In Indiana for property corners, we have to have company name and number or land surveyor name and number on caps and tags. So for conc./asphalt, I w...

10 years ago
Reply
RE: Countersinking Shiners

I have looked and looked. Aside from a $300 bit from Berntsen or similar tunneling bit, the closest solution I have found is what Kent uses (above) -...

10 years ago
Reply
RE: Contest to Automate ALTA Surveys. WTF........

Oh this is easy...you can just cut and paste a gis screen shot of the parcel, the title commitment, and a VERY LARGE DISCLAIMER together, right? Seems...

10 years ago
Page 10 / 13