@ladd-nelson I had contact with you regarding the 2 issues with Carlson. I have tried contacting you and technical support recently regarding the seco...
@mark-silver teqc +qc bnt4154o.20o This is working now
Thanks that seem to be the issue. I changed it from .o to .20o
Teasing all this out at the moment. I believe it is to be tied to 3 CORS stations closest one being 25km.
Very sad news.
@bill93 Some reports on here recently that the old Topcon Tools was giving some seriously incorrect results. A new version of Magnet tools is fairly ...
See the following on Carlson forums Look for posts here as well from the late Dent Cermak (cptdent) he covered this many times.
@john-hamilton "I do trigs using the S6 up to 200 m without any HI's or HT entering in and match differential leveling at the mm level." Would you mi...
You name it it has been tested. Two different 5 second robots, all Trimble gear, different data collectors, surveyors, dealers testing, distances, pri...
Very old thread, but I believe this is a problem with the calibration procedures at some Trimble shops. This vertical error is not uncommon and has no...
@picklespieandsauce Yes pivot, that is what it is there for.
I export a .dc file from the controller and import to rw5 file in Carlson. Then I process in Survnet Least squares, it works well as I can combine raw...
@ladd-nelson Done
Not my experience here with technical support. 2 separate issues unresolved and ignored over past year. Great software otherwise.
Can you share?
@brad83091 I bought a data collector from them with no issues. Spoke on the phone and they were helpful.
@paul-in-pa I am not finding anything other than a previous post of mine. Is it here you have seen it?