RE: Tablet data collector

Do Lieca use the newest version of the ToughPad as Panasonic now offers it with 8gb ram a 256gb SSD and the newer supposedly more power efficient m se...

8 years ago
Reply
RE: Tablet data collector

Not a Mesa 2 but we are using Getac T800 so far they are very nice to use other than the added weight and bulk. I think whether or not you should get ...

8 years ago
Reply
RE: What happened to the respected surveyor???

Just to ask what percentage of your guys clients actually want to get a survey vs a means to an ends to accomplish something else??

8 years ago
Reply
RE: Elevation Certificate Diagram

2A was what I thought as well. The twist is that the fill was supposed to be placed around 2011 to bring the basement floor up and the grade around th...

8 years ago
Topic
Replies: 4
Views: 1
Reply
RE: DOT RTN / VRS guru suggestions needed.

leegreen, post: 417026, member: 2332 wrote: That's what I meant by different datum. Since KEYNET website doesn't clearly state their datum, it is prob...

8 years ago
Reply
RE: DOT RTN / VRS guru suggestions needed.

I figured that is what you meant but I think he may have thought you just meant in the data collector

8 years ago
Reply
RE: DOT RTN / VRS guru suggestions needed.

You may have them set to the same datum but it would be helpful to know what datum the corrections are broadcast for

8 years ago
Reply
RE: Atmospheric corrections

There is an app that has station pressure

8 years ago
Reply
RE: SOKKIA ROBOT & RC-PR5

We have had SRX SX and now an IX the only 2 problems we have had is one ran over by a backhoe, 1 broken RC-4 antenna and the tracking went on the 7 ye...

8 years ago
Reply
RE: Truck Bed Recommendations ?

We have retrax and really like them

8 years ago
Reply
RE: Carlson Tin to Field Data

Should be in surface menu elevation difference

8 years ago
Reply
RE: What is done when total station sent in for calibration?

Shop is probably at 70 degrees what is the temperature of the spot you are checking the instrument.

8 years ago
Reply
RE: Cordless Jackhammer recomendations?

Under 6 or 8" I would think the Milwaukee 9/16" to 1" that has a hammer only mode would work. Anything 1' or more I would go either generator, or the...

8 years ago
Reply
RE: Cordless Jackhammer recomendations?

How deep are you going down

8 years ago
Reply
RE: Setting temporary points for settlement monitoring

Dewatering, pile driving, surchargeing, tunneling, rammed aggregate piers. Depending on how close to the construction it could be a lot of things or j...

8 years ago
Reply
RE: Setting temporary points for settlement monitoring

Retro reflective targets is how I would do it I would be very careful about puting a bench near the area to be monitored. Let's say you have a 3" gun ...

8 years ago
Reply
RE: Verticality in an Existing Highrise

If you have time try poking around on Leicas website if I remember there were some articles about alternative methods for vertical construction.

8 years ago
Reply
RE: Urban Tools Recommendations

I like the Milwaukee m18 line I can run a angle grinder, drill, and sds plus hammer drill off the same battery. The up side is the sds plus can put a ...

8 years ago
Reply
RE: Urban Tools Recommendations

I like a to use a hammer drill start a very shallow 3/8" hole then drill a 5/32" through it and set a tapcon screw for a nice countersunk control poin...

8 years ago