Reply
RE: Set up total station on the tilt to look vertically down.

> Why not set the instrument up correctly and use a 90 degree optical prism so your zenith angle can be exaggerated to 60+ degrees? I used on when...

12 years ago
Reply
RE: Nikon Nivo 2C

Still available if anyone is interested.It's a really nice & portable instrument.

12 years ago
Forum
Reply
RE: Best CAD Mouse

"Microsoft Optical Wheel Mouse" is what I've settled on. Seems to fit my hand more comfortably than others. The wheel / button action is right as well...

12 years ago
Reply
RE: I Phone connection to DC

Bluetooth should be possible but I can't get my TSC3 to connect to my Android phone. Also it should recognise my android phone connected by cable as a...

12 years ago
Reply
RE: The instrument height problem

> Is the offset to center of axes the same? I didn't think they are.Yep Trimble S6 is 196mm above the tribrach plate, same as Leica.

12 years ago
Reply
RE: The instrument height problem

> :good: > > For Leicas, anyway.And Trimble. Only problem is getting the clip onto the tribrach. My tribrachs are all Leica or Topcon. Topcon...

12 years ago
Reply
RE: Prism constant question

> You do not need a known distance to determine the prism offset (actually combined instrument and prism, but typically called the prism offset, as...

12 years ago
Reply
RE: The instrument height problem

Another thing to consider> Is everyone making absolutely certain that their instrument is not sinking over time. A prime example of that was occur...

12 years ago
Reply
RE: Prism constant question

Unlike the Leica round prism the GMP111-0 isn't a nodal point prism so you would get small pointing errors if the miniprism wasn't perfectly facing th...

12 years ago
Reply
RE: Prism constant question

> > I know they are both 0mm constant, so should be okay, but I am not 100% sure.> > They're not the same. I put together this graphic to...

12 years ago
Reply
RE: Prism constant question

There are 2 Leica mini prisms that look very similar/identical but have different prism constants.1) GMP111-0 (current model) has a Leica 0.0 constant...

12 years ago
Reply
RE: DXF question

The DXF files are corrupt or in some way substandard.I would simply ask the client to check their software output by opening the DXF files (with Autod...

12 years ago
Reply
RE: S6 C&R corrections

Yes I see reference to having corrections on the instrument in the Access manual but I can't find how to switch them on or off on the S6 so I can only...

12 years ago
Topic
Replies: 8
Views: 528
Topic
12 years ago
Forum
Replies: 8
Views: 404
Reply
RE: The Problem With Laser Levels

This is all true and I wouldn't have thought of it. The divergence of a laser level is quite great as well (if you have ever seen it in the dark). I w...

12 years ago
Reply
RE: Trimble multitrack target battery

Tapping on to a desk edge whilst holding the release switches open.Then levering it out with a small screwdriver in the groove.All very gently of cour...

12 years ago
Reply
RE: ring ring ~ bye bye

try adblock in your browser:-)

12 years ago