Last seen: June 2, 2026 12:10 pm
First off, I do believe RTK is good and can be checked. How do you know your total station is shooting good distances and turning good angles? By ch...
What are they then if not brokers?
I know our contract has a termination clause that will be paid for the work performed to date. We would then just start a new job with new terms of c...
If you have a contract there should be language in it to protect you from this kind of thing. If you don't have a contract you might want to look at ...
One time I tried to get a fix in tree cover during the winter. It was pretty thick with some large trees. I was trying to get the shot, then I was g...
Are you saying you have done the job on a assumed coordinate system and then localized you GPS to this coordinate system? If so, it doesn't sound lik...
I also have had bad intializations hold for a while. This is usually when you walk by something, like a tree or building and it loses lock, regains i...
I've done a couple, and yeah, kind of a pain.
I've got two of them, neither of which work sitting above my desk. Yours must be different. Mine has a 9 pin, that looks a lot like a serial port on ...
In the top of the unit, there should be a small round port, this is how you power the unit. It looks like a port you would charge a laptop by. The 7 ...
I've been using TDS software for years so I'm a little biased, but if you are using a SDR33 I would consider a Ranger with TDS software a serious step...
I guess what I was saying what if I sent you a C3D drawing where the points were locked. In Carlson, would they still be locked keeping you from eras...
I know in C3D you can lock points. I don't know if they are still locked in your drawing? If they aren't locked, you can just use the erase command ...
I'm not a huge fan of such a thing. The exception might be for a construction project where you know the corner will get knocked out and its just the...
I think the point I was trying to make, although my words probably did a poor job of it, is in this case, 13 feet is too much. How do we know if its ...
I'd probably ignore the corner. If there were other errors in this subdivision, I'd probably use it but if everything else fits within a few tenths l...
Does Mr. Quickclose work for the realators, Hookem, Fleecem and Screwem?
What was the weight limit on that bridge?I'm not sure of what it was posted at, but I think it was 4 tons and the concrete truck was full.
I agree, the 1/2 is one half of a link. I see that done all the time in my area, although it might be worded a little different.