RE: Vertical Control

John Hamilton, post: 419826, member: 640 wrote: I should add that SLAC has done a lot of research on digital levels, and have published a number of pa...

9 years ago
Reply
RE: Vertical Control

FrancisH, post: 419799, member: 10211 wrote: Again never used invar rods in my life. Weight alone based on specs is 2x or 3x heavier than fiberglass s...

9 years ago
Reply
RE: Vertical Control

FGCS specs for both First and Second Order leveling require invar rods. They can - and generally are, these days - barcode rods, but they have to be ...

9 years ago
Reply
RE: Vertical Control

John Putnam, post: 419760, member: 1188 wrote: Jim, I would be more suspect of the bench over the CORS.There's no question that the BM has subsided, t...

9 years ago
Reply
RE: Pics from the field

It must feel strange to be working in the RR ROW without looking over your shoulder every 2 minutes to see if the RR police are on their way to kick y...

9 years ago
Reply
RE: SurvCE question

Luke J. Crawford, post: 419523, member: 11382 wrote: An issue I do have is the L/R if picked before distance is entered will switch back to R.That's n...

9 years ago
Reply
RE: Vertical Control

FrancisH, post: 419576, member: 10211 wrote: In 4 hours you could run a 5 km loop and your results would be within 1st/2nd order if you will be using ...

9 years ago
Reply
RE: Javad LS Question

Adam, post: 419549, member: 8900 wrote: Beast mode can be used with a network.I think this is worthy of emphasis: you *can* (and I do) use 5Hz correc...

9 years ago
Reply
RE: Great Online Tool for Checking CORS Trending

The large inelastic drop for P271 in mid-2014 was at least partially the result of an intensive pumping effort associated with a groundwater substitut...

9 years ago
Reply
RE: Vertical Control

MightyMoe, post: 419454, member: 700 wrote: I realize this isn't so in other areas of the countryLast week I did a 4-hour session on a First Order Cla...

9 years ago
Reply
RE: Great Online Tool for Checking CORS Trending

PLSB and P271 (a few miles away) are stations that I never constrain for vertical. Both are in a subsiding area, and sometimes it's a pretty wild rid...

10 years ago
Reply
RE: SurvCE question

I haven't seen either of those problems, knock wood. What version, and what platform?

10 years ago
Reply
RE: Vertical Control

FrancisH, post: 419396, member: 10211 wrote: only difference between RTK and static sessions is the RT in RTKThe difference is in using local BMs inst...

10 years ago
Reply
RE: SurvCE question

On a related matter -- in effect, though probably not in cause -- I've noticed that, under certain conditions that I've not been able to intentionally...

10 years ago
Reply
RE: Vertical Control

FrancisH, post: 419219, member: 10211 wrote: So if your project needs accuracy to be in the 1st order level (4mm closure/km) then your rtk results won...

10 years ago
Reply
RE: Dead Rebar

The first Schonstedt video above contains a pretty glaring goof: the guy cautions that stainless steel will be harder to detect because it has "littl...

10 years ago