RE: Breaklines

An easy to remember rule is that if you feel it as you walk over it then treat it as a break line. Thus breaks of slope and distinct rollovers will re...

13 years ago
Reply
RE: UAV

Yes, about 5 companies is probably correct: a very small percentage of the market here. UK regulations are contained within the Civil Aviation Authori...

13 years ago
Reply
RE: UAV

Not quite true about the use in England. The technique is starting to appear (perhaps less than 0.1 percent of all suitable jobs).Restrictions are qui...

13 years ago
Reply
RE: Trimble R8 static download

Just to clarify the last post - I should have started by saying that you need to check the actual live job is recording. A dummy can be checked as rec...

14 years ago
Reply
RE: Trimble R8 static download

To make sure the receiver is recording static data, once it is running go to the Instrument menu on the controller and select "Import from Receiver". ...

14 years ago
Reply
RE: GPS - Network vs Independent Base Station

Agreed. I should have said that we also use 15 minutes minimum. GPS on top of the instrument is very handy when you are in wooded areas (such as corri...

14 years ago
Reply
RE: GPS - Network vs Independent Base Station

We don't use VRS, but we are now starting to be asked to carry out work where somebody else has been unable to get "GPS signals". There doesn't seem t...

14 years ago
Topic
Reply
RE: monitoring

I'm just pricing a job where we will be reading levels to 0.01mm, probably achieving an accuracy of 0.03mm, using invar staves and an N3.As others hav...

14 years ago
Reply
RE: Expert Witness

I long ago adopted the policy of quoting an expert witness fee in the form : "75% of the hourly fee charged by the instructing lawyer".This way ensure...

14 years ago
Reply
RE: Robotic sighting

Instruments all appear to "take" the best signal they get back, so with a 360 degree prism where there will be more than one reference visible, the re...

14 years ago
Reply
RE: Emergency Topcon Recell

Ni-MHMost total stations draw considerably less than 0.8 amps momentarily at the peak point of the measuring cycle. Average draw is in low milliamps, ...

14 years ago
Reply
RE: Network Rover vs Base/Rover

Question about virtual base set-upA useful piece of research, conducted by Newcastle-upon-Tyne University is available on the UK Survey Association we...

14 years ago
Reply
RE: Levelling Staff Expansion

The temperature of 68 Fahrenheit is also 20 Centigrade, which is the reference standard temperature used outside the USA. As noted, most calibration l...

14 years ago
Reply
RE: Levelling Staff Expansion

Can I add a couple of thoughts from my side of the pond.I've monitored a large shopping complex for some 25 years now. It was built on an old power st...

14 years ago