Notifications
Clear all
Grads&Meters
@gradsmeters-2-2-2
Registered
Joined: Nov 18, 2016
Topics: 1 / Replies: 17
Reply
RE: 360 prisms

I asked about this from Leica few years ago. The triangle shaped mirror "centers" on Leica type 360 prisms (GRZ4, MPR122 etc.) are offeset from prism...

2 years ago
Reply
RE: Setting up control for construction site

Hey, for me it goes something like this. Internal accuracy of your control points is what matters most when it comes to construction. Best way to ac...

2 years ago
Reply
RE: Height discrepancy between laser beam and prism

Hey, Im not quite sure what you trying to say. Try to be more specific. Are you checking sticker target heights with GMP111 backspike or what? Few ...

3 years ago
Reply
RE: What are the Leica iCON total stations ?

@johnymal No, i dont know anyone. I believe SurvCE is not very popular in Europe.

3 years ago
Reply
RE: What are the Leica iCON total stations ?

Hey, Ive been using Leica Icon for about two years now with MS60. Before this i had captivate for about 3 years and smartworx before that. Few flaws...

3 years ago
Reply
RE: Client wants a survey of inside of lift core. How?

Id forget the plumbs/zenith lasers etc. Setup total station to the elevator pit and run upwards with a prism pole. Stick it inside elevator shaft at ...

5 years ago
Reply
RE: Captivate vs Icon site

@jflamm Measurement mode has nothing to do with this issue. Im talking about separate distance measurement and angle recording. Normally with leica...

5 years ago
Reply
RE: Captivate vs Icon site

Noticed that Icon distance measurement doesnt lock XY into place after measurement like captivate does. If you shoot on vertical facade and start roll...

5 years ago
Reply
RE: Captivate vs Icon site

Sticker range issue could be that ICR70 has R500 laser while the TS16 i used had R1000. ICR70 has hard time measuring past 50 meters to slightly angle...

5 years ago
Topic
Replies: 8
Views: 7
Reply
RE: Leica TS15 - split Face I and Face II observations

John has is right. Measure FN->2face stores an average which cant be split Storing face1 and face 2 with the same point number creates 3 invidual p...

5 years ago
Reply
RE: ppm chart, or calculator

PPM starts to matter when your measuring longer distances (100 meters+) or doing something extra precise like control points/industrials etc. I usuall...

5 years ago
Reply
RE: Interior layout instrument

@squowse This is correct. If you shoot angled wall shots the distance reading is taken slightly off  from the center of the red dott. Same is t...

5 years ago
Reply
RE: Interior layout instrument

If you are doing reflectorless staking on walls keep in mind that the measured distance starts to get bad after about 45 degree or so. This is because...

5 years ago
Reply
RE: Check rod height w/ Leica 360 prism

Hello,I called to leica support few years ago about grz4 elevation problem. Depending on which mirror you aim at the height is +2mm or -2mm.The explan...

8 years ago
Page 1 / 2